Herramientas versátiles que combinan potentes características con una operación intuitiva son herramientas adecuadas para desarrolladores.
ER-Soft

Herramientas versátiles que combinan potentes características con una operación intuitiva son herramientas adecuadas para desarrolladores.


Herramientas versátiles que combinan potentes características con una operación intuitiva son herramientas adecuadas para desarrolladores. ER-Soft ofrece un amplio rango de productos para análisis físicos y de protocolo para distintas redes industriales.


IXXAT

Código: 1.14.0415.00002

Handheld diagnostic device for the physical and
logical analysis of CAN bus systems

CANtouch® is a battery-operated handheld diagnostic device for the physical and logical analysis of CAN, CANopen, DeviceNet o

  • Supported protocols: CAN, CANopen, DeviceNet, SAE J1939
  • Baud rates (10 kBit/s ... 1 MBit/s)
  • Measurements designed as Apps
    - Bus Status (Bus traffic load)
    - Bus Errors (Active and passive frame errors)
    - Bus Voltages (CAN supply voltage and shield voltage)
    - Common Mode Voltage
    - CAN Levels (absolute / differential)
    - Bus Wiring (Short-circuits, interruptions, loop resistances, cable length)
    - Node Measurement (Quality level, Dist.-free voltage range, Edge steepness, Oscilloscope disp.)
    - Protocol Monitor
  • Including six apps, three additional apps via license
Languages English, German
Bus systems (CAN type) CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325-2), SAE J1939
Bit scanning 64 times, 10240 sampling points
Supported baud rates > 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s; > Additional user defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s; > Automatic recognition via baud rate scan, bit timing adjustable
Power supply and battery > Built-in: Rechargeable lithium-ion battery > External power supply: SELV DC 14 V; operation only via included 35 W wide range power supply > Duration: Standby: up to 500 hrs.; Activated: Up to 36 hrs.; Measurements: up to 6 hrs. > Charging times: fast charge to 80 % in about 1 hr.; fully charged in about 2 hrs.
Housing Aluminum housing, cover glass
Operating temperature 5 °C ... 40 °C
Protection IP20 according to EN 60529
Dimensions/Weight 186 x 102 x 37 mm; about 860 g

CANtouch

IXXAT

Código: 1.12.0157.00000

Powerful CANopen service and diagnostics
tool for service staff and developers

The IXXAT CANopen® Device Manager is a versatile and upgradeable tool aimed at device test, diagnostics, and field service tasks. Built aroun

  • Comprehensive CANopen functionality including NMT node and error control services, SDO client, PDO consumer and producer
  • Support for SDO block transfer
  • LSS master functionality according to CiA 305  
  • Configuration and firmware download according to CiA 302
  • Customized plug-in modules covering dedicated CANopen diagnostics or service functionality

CANopen Device Manager

IXXAT

Código: 1.12.0360.90000

Configuration editor and code generator for J1939 projects 

The SAE J1939 Designer is a powerful tool for creating and management of J1939 projects. A J1939 project consists of the definition of parameters (SPNs) and mes

  • Enables cross product configuration and code generation
  • Increase the development speed by avoiding errors caused by inconsistent data sets
  • Supports canAnalyser, SAE J1939 API and SAE J1939 protocol software (together with the extensions)
  • Supports the single and multi instance version of the J1939 protocol software
  • Allows an easy configuration of the protocol software exactly to the needs of the application
  • Provides an application specific user interface on parameter level for the protocol software
  • Allows the definition of proprietary messages and parameters via a comfortable graphical user interface

SAE J1939 Designer

IXXAT

Código: 1.24.0034.03100

EtherNet/IP Scanner Simulator Tool

EIPScan is a Microsoft Windows-based software application that simulates an EtherNet/IP Scanner. EIPScan is an extremely useful tool for testing and debugging EtherNet/IP products during dev

  • Connect to devices through one or more Ethernet interfaces on the PC
  • Browse the network(s) for devices or manually add them
  • View and modify I/O data (binary or hexadecimal)
  • Automated test of Class 1 and Class 3 connections
  • Queuing of multiple UCMM Requests

EIPScan

IXXAT

Código: FRC-EP170

The Embedded Platform forms the basis for manifold automotive testing and analysis applications in vehicles and test benches – both, with the IXXAT ACT tools as well as with customer-specific software solutions.

 

    undefined
FlexRay A/B channel (also available as CAN-only version without FlexRay)1 x (10 MBit/s)
CAN High Speed max. 4 x
CAN Low Speed max. 1 x
LIN 1 x
K-Line 1 x
RS232 1 x
USB 2 x (Host and Device)
Digital in 4 x
Digital out 4 x
SDHC card slot 1 x
Internal expansion slots 2 x mPCIe form factor
External extensions Wi-Fi, USB devices
Others Prepared: GSM/GPS, Bluetooth and Automotive Ethernet
PC connection Ethernet 10/100 MBit/s, Wi-Fi or USB 2.0
Plugs Standard plug for PC; DSub plug for fieldbus
Temperature range -40 °C ... +80 °C
Power supply 6-36 V DC; 350 mA typ. at 12 V
Dimensions 142 x 113 x 40 mm

FRC-EP 170

IXXAT

Código: FRC-EP190

The Embedded Platform forms the basis for manifold automotive testing and analysis applications in vehicles and test benches – both, with the IXXAT ACT tools as well as with customer-specific software solutions.

 

    undefined
FlexRay A/B channel 2 x (10 MBit/s)
CAN High Speed max. 8 x
CAN Low Speed max. 2 x
CAN FD max. 2 x
LIN 2 x
K-Line 2 x
RS232 1 x
USB 2 x (Host and Device)
Digital in max. 4 x
Digital out max. 4 x
Analog in (12 bit) max. 4 x
Further interfaces optional EtherCAT-Slave I/O
SDHC card slot 1 x
Internal expansion slots 2 x (FlexRay, CAN, CAN-FD, EtherCAT)
External extensions Wi-Fi, USB devices
Others Prepared: GSM/GPS, Bluetooth and Automotive Ethernet
PC connection Ethernet 10/100 MBit/s, Wi-Fi or USB 2.0
Plugs Standard plug for PC; DSub plug for fieldbus
Temperature range -40 °C ... +80 °C
Power supply 6-36 V DC; 420 mA typ. at 12 V
Dimensions 182 x 113 x 50 mm

FRC-EP 190

IXXAT

Código: 1.12.0133.31000

Powerful Tool for Development, Testing and Service

The canAnalyser is a versatile tool for the development, testing and servicing of CAN, CAN FD and LIN based systems. The software package is based on a modular concept and a

  • Interfaz intuitiva y configurable.
  • Análisis de redes fácil e intuitivo, almacenamiento de datos en el disco duro
  • Potente y versátil, con time-stamp de alta precisión en las tramas CAN
  • Permite Análisis posterior en modo offline

canAnalyser lite/standard

IXXAT

Código: 1.12.0166.31000

Powerful Tool for Development, Testing and Service

The canAnalyser is a versatile tool for the development, testing and servicing of CAN, CAN FD and LIN based systems. The software package is based on a modular concept and a

  • Interfaz intuitiva y configurable.
  • Análisis de redes fácil e intuitivo, almacenamiento de datos en el disco duro
  • Potente y versátil, con time-stamp de alta precisión en las tramas CAN
  • Permite Análisis posterior en modo offline

canAnalyser lite/standard

IXXAT

Código: 1.12.0145.30000

CANopen Interpreter for canAnalyser

As an addition to the canAnalyser, the CANopen Module interprets all received CAN messages according to the CANopen specifications CiA301 (incl. SDO block transfer), CiA302 (incl. Flying Maste
  • Simplifies analysis of CANopen networks and devices
  • Direct display of all CANopen messages according to CANopen specification
  • Easy integration into canAnalyser test environment

CANopen Module

IXXAT

Código: 1.12.0148.30000

DeviceNet Interpreter for canAnalyser

As an addition to the canAnalyser, the DeviceNet module interprets all received CAN messages according to the ODVA DeviceNet standard and displays the received parameters according to Messag
  • Simplifies analysis of DeviceNet networks and devices
  • Direct display of all DeviceNet messages according to DeviceNet specification
  • Easy integration into canAnalyser test environment

DeviceNet Module

IXXAT

Código: 1.12.0149.30000

SAE J1939 Interpreter for canAnalyser

As an addition to the canAnalyser, the J1939 Module provides the display of received messages according to the SAE J1939 notation. This includes the interpretation of received J1939 messages
  • Simplifies analysis of SAE J1939 networks and devices
  • Direct display of all SAE J1939 messages according to SAE J1939 specification
  • Easy integration into canAnalyser test environment

J1939 Module

IXXAT

Código: 1.01.0097.00000

Installation tester for CAN networks

CANcheck allows users to analyze CAN networks during commisioning, maintenance and helps searching faults. This battery-operated, hand-held device connects to the CAN network t

  • Cable test with network switched off and operational test with network switched on
  • Wiring test: test of the resistances between all pins of the CAN-connector (assignment in accordance with CiA), providing assessment based on pre-defined threshold values
  • Terminal resistance test: measurement of the resistance between CAN_H and CAN_L
  • Cable length: measurement of cable length via pulse-time delay, cable impedance
  • Measurement of the signal level: absolute and differential signal level listed according to identifier
  • Baud rate detection: detection of baud rate of the tested CAN system
  • Identifier scan: determination of all identifiers transmitted and display of reception frequency
  • CANopen mode: Signal level and reception frequency listed according to node-ID
  • Bus load: measurement of the current bus load of the CAN system
  • Error frames: number of error frames per time unit
  • User’s guide: test instructions before the test, OK or error message after the test, continuation after acknowledgement
  • Multilingual: test instructions in German or English
Display 128 x 64 pixels; background light can be switched on or off
Keypad Touch-sensitive keypad with 6 keys
Switch on/off Switch on by pressing any key; switches off automatically after 10 mins.
USB port USB 2.0 (full speed)
CAN interface ISO 11898-2 High-Speed CAN
Power supply4 x 1.5 V Mignon Battery (AA) or USB
Operating time approximately 24 hrs. with a battery capacity of 2850 mAh
Temperature range 0 ºC ... +50 ºC
Housing and dimensions Sturdy aluminum housing 116 x 160 x 34 mm (W/H/D)

CANcheck

IXXAT

Código: 1.14.0415.00000

Handheld diagnostic device for the physical and
logical analysis of CAN bus systems

CANtouch® is a battery-operated handheld diagnostic device for the physical and logical analysis of CAN, CANopen, DeviceNet o

  • Supported protocols: CAN, CANopen, DeviceNet, SAE J1939
  • Baud rates (10 kBit/s ... 1 MBit/s)
  • Measurements designed as Apps
    - Bus Status (Bus traffic load)
    - Bus Errors (Active and passive frame errors)
    - Bus Voltages (CAN supply voltage and shield voltage)
    - Common Mode Voltage
    - CAN Levels (absolute / differential)
    - Bus Wiring (Short-circuits, interruptions, loop resistances, cable length)
    - Node Measurement (Quality level, Dist.-free voltage range, Edge steepness, Oscilloscope disp.)
    - Protocol Monitor
  • Including six apps, three additional apps via license
Languages English, German
Bus systems (CAN type) CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325-2), SAE J1939
Bit scanning 64 times, 10240 sampling points
Supported baud rates > 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s; > Additional user defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s; > Automatic recognition via baud rate scan, bit timing adjustable
Power supply and battery > Built-in: Rechargeable lithium-ion battery > External power supply: SELV DC 14 V; operation only via included 35 W wide range power supply > Duration: Standby: up to 500 hrs.; Activated: Up to 36 hrs.; Measurements: up to 6 hrs. > Charging times: fast charge to 80 % in about 1 hr.; fully charged in about 2 hrs.
Housing Aluminum housing, cover glass
Operating temperature 5 °C ... 40 °C
Protection IP20 according to EN 60529
Dimensions/Weight 186 x 102 x 37 mm; about 860 g

CANtouch

IXXAT

Código: 1.14.0402.00001

Powerful tool for analysis of
CAN bus physics and CAN protocol

The CAN-Bus-Tester 2 is a universal measuring instrument for the commissioning, analysis, monitoring, troubleshooting and maintenance of CAN bus systems.

  • Support of CAN, CANopen, DeviceNet and SAE J1939 systems 
  • Analysis of the signal-to-noise ratio of all telegrams (level, flanks, faults)
  • Integrated oscilloscope with data interpretation for telegram analysis
  • Comprehensive trigger conditions for fault localization (logical and physical errors)
  • Monitoring of bus status, bus load, error telegrams
  • Wiring test (termination resistance, short circuits, interruptions, loop resistance, line length)
  • Automatic baud rate detection
  • Simple connection to CAN systems thanks to automatic baud rate detection and BusScan
  • Simple operation via Windows program
  • Simple generation of test protocols
  • CAN monitor for transmission and reception of CAN messages (optional)
Use CAN according to ISO 11898-2 (High-Speed) with 11-bit or 29-bit identifier (CAN 2.0A and 2.0B)
Baudrate 5 k, 10 k, 20 k, 33.3 k, 50 k, 62.5 k, 75 k, 83.3 k, 100 k, 125 k, 200 k, 250 k, 500 k, 800 k, 1000 kBit/s
Baudrate detection All supported baudrates
Bit scanning 64x, 10240 scanning points
Trigger output BNC-socket, electrically isolated
Connection to CAN bus Passive, 2 x 9-pole SUB-D connector
PC connection Via USB, electrically isolated
Supply voltage 9 ... 36 V DC, DIN 45323 low-voltage socket; 0.15 ... 0.55A
Dimensions and wight 40 x 134 x 170 mm (H/W/L), approx. 600 g; With case: 504 x 354 x 119 mm, approx. 5000 g
Safety/protection EN 60950: 2003-03 / IP 20 according to EN 60529
EMC EN 61000-3-2: 2000, +A1: 2000, +A2: 2004 EN 55022: 1998, +A1: 2000, +A2: 2003 EN 61000-6-2: 2001
Temperatur range Operation: +5 °C ... +40 °C; Storage: -20 °C ... +60 °C

CAN-Bus-Tester 2 (CBT2)

IXXAT

Código: 1.14.0402.00002

Powerful tool for analysis of
CAN bus physics and CAN protocol

The CAN-Bus-Tester 2 is a universal measuring instrument for the commissioning, analysis, monitoring, troubleshooting and maintenance of CAN bus systems.

  • Support of CAN, CANopen, DeviceNet and SAE J1939 systems 
  • Analysis of the signal-to-noise ratio of all telegrams (level, flanks, faults)
  • Integrated oscilloscope with data interpretation for telegram analysis
  • Comprehensive trigger conditions for fault localization (logical and physical errors)
  • Monitoring of bus status, bus load, error telegrams
  • Wiring test (termination resistance, short circuits, interruptions, loop resistance, line length)
  • Automatic baud rate detection
  • Simple connection to CAN systems thanks to automatic baud rate detection and BusScan
  • Simple operation via Windows program
  • Simple generation of test protocols
  • CAN monitor for transmission and reception of CAN messages (optional)
Use CAN according to ISO 11898-2 (High-Speed) with 11-bit or 29-bit identifier (CAN 2.0A and 2.0B)
Baudrate 5 k, 10 k, 20 k, 33.3 k, 50 k, 62.5 k, 75 k, 83.3 k, 100 k, 125 k, 200 k, 250 k, 500 k, 800 k, 1000 kBit/s
Baudrate detection All supported baudrates
Bit scanning 64x, 10240 scanning points
Trigger output BNC-socket, electrically isolated
Connection to CAN bus Passive, 2 x 9-pole SUB-D connector
PC connection Via USB, electrically isolated
Supply voltage 9 ... 36 V DC, DIN 45323 low-voltage socket; 0.15 ... 0.55A
Dimensions and wight 40 x 134 x 170 mm (H/W/L), approx. 600 g; With case: 504 x 354 x 119 mm, approx. 5000 g
Safety/protection EN 60950: 2003-03 / IP 20 according to EN 60529
EMC EN 61000-3-2: 2000, +A1: 2000, +A2: 2004 EN 55022: 1998, +A1: 2000, +A2: 2003 EN 61000-6-2: 2001
Temperatur range Operation: +5 °C ... +40 °C; Storage: -20 °C ... +60 °C

CAN-Bus-Tester 2 (CBT2)

Actualmente estamos trabajando en mostrarte los mejores resultados, si no encuentras el producto que buscas contacta con nosotros a través de info@er-soft.com o al número Tel. +34 916-408-408
Bienvenido a ER-Soft.
ER-Soft con la ley orgánica de protección de datos
Política de cookies.
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación.
Si continúa navegando, consideramos que acepta su uso.
Más información pulsando aquí
X

¿Necesitas ayuda? Click

ayuda ER-Soft
X
Consulta a ER-Soft. *

 

*

 

* *Campos obligatorios.




X