ER-Soft dispone de una amplia gama de pasarelas de comunicación industrial para la mayoría de buses de campo. +AS-i interface Maestro +BACNet MS/TP +BACNet/IP +Bluetooth +CANopen +CANOpen Maestro +CANOpen esclavo +CC-Link esclavo +CC-Link IE Field esclavo +Common Ethernet +CompoNet +Controlnet adaptador/esclavo +Dali +Devicenet adaptador/esclavo +DNP3 +Devicenet Maestro +EtherCAT esclavo +Ethernet IP adaptador/esclavo +Ethernet IP Maestro +M12 for IP65/67 devices +Fieldbus Foundation +FIP esclavo +Hart +Interbus CU esclavo +Interbus FO esclavo +IEC-61850 +IEC-60870-5-104 +J1939 +KNX +Lonworks +M-Bus +Modbus Plus esclavo +Modbus RTU Maestro +Modbus RTU esclavo +Modbus TCP Maestro +Modbus TCP esclavo +PowerLink +MPI +PPI +Profibus Maestro +Profibus esclavo +Profibus PA +Profinet IO Device +Profinet IRT Device +Profinet IRT fibra optica device +RS232 +RS485 +Sercos III +USB +IEC60870-5-101 Maestro & esclavo +IEC60870-5-103 Maestro +IEC60870-5-104 Servidor & Cliente - KEMA certified +IEC61400-25 +COMLI Maestro +DLMS/IEC1107 +DF1 +SNMP +RS422 +CAN +CAN FD +LIN +ASCII +Spinel +Modbus ASCII +.NET Framework +FIPIO esclavo +USS Master +Digital-inputs +Digital-output


Anybus
 x-gateway-cops-lons

Código: AB7898

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and Lonworks networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - Lonworks Slave

Anybus
 x-gateway-cops-intfo

Código: AB7889

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and Interbus Fiber Optic networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - Interbus FO Slave

Anybus
 x-gateway-cops-intcu

Código: AB7883

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and Interbus networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - Interbus CU Slave

Anybus
 x-gateway-cops-fip

Código: AB7876

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and FIPIO networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - FIPIO Slave

Anybus
 x-gateway-eipm-cops

Código: AB7677

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between EtherNet/IP and CANopen networks.
  • Fast copying of cyclic I/O data between EtherNet/IP and CANopen networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Powerful Scanner interface eliminates the need for a PLC controller on the EtherNet/IP network
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • 10/100 Mbit/s Dual-port EtherNet/IP adapter interface with IT functionality
  • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
  • Optional control status information added to I/O data for diagnostic purposes
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway – EtherNet/IP Scanner - CANopen Slave

Anybus
 x-gateway-cops-eips

Código: AB7838

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between EtherNet/IP and CANopen networks.
  • Fast copying of cyclic I/O data between EtherNet/IP and CANopen networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • 10/100 Mbit/s Dual-port EtherNet/IP adapter interface with IT functionality
  • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
  • Optional control status information added to I/O data for diagnostic purposes
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway – EtherNet/IP Adapter - CANopen Slave

Anybus
 x-gateway-cops-ects

Código: AB7691

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and EtherCAT networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - EtherCAT Slave

Anybus
 x-gateway-cops-devm

Código: AB7816

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between DeviceNet and CANopen networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Powerful Scanner interface for DeviceNet eliminates the need for a PLC controller
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway – DeviceNet Scanner - CANopen Slave

Anybus
 x-gateway-cops-devs

Código: AB7859

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and DeviceNet networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - DeviceNet Adapter

Anybus
 x-gateway-cops-cnts

Código: AB7868

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and ControlNet networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - ControlNet Adapter

Anybus
 x-gateway-cops-ccls

Código: AB7897

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and CC-Link networks.
  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - CC-Link Slave

Anybus
 x-gateway-cops-cclief

Código: AB7963

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and CC-Link IE Field networks.
  • Fast copying of cyclic I/O data between the two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
  • Optional control status information added to I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - CC-Link IE Field Slave

Anybus
 x-gateway-cops-cops

Código: AB7894

The Anybus X-gateway allows you to seamlessly inter-connect/extend PLC control systems and their connected devices on a CANopen network.
  • Fast copying of cyclic I/O data between two extended CANopen networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway - CANopen Slave - CANopen Slave

Anybus
 x-gateway-cfns-prts

Código: AB7954

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CC-Link IE Field and PROFINET networks.
  • Fast copying of cyclic I/O data between the two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
  • Optional control status information added to I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway – CC-Link IE Field Slave - PROFINET-IO Device

Anybus
 x-gateway-cfns-pdpm

Código: AB7959

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CC-Link IE Field and PROFIBUS networks.
    undefined
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Anybus X-gateway – CC-Link IE Field Slave - PROFIBUS Slave

Actualmente estamos trabajando en mostrarte los mejores resultados, si no encuentras el producto que buscas contacta con nosotros a través de info@er-soft.com o al número Tel. +34 916-408-408
Bienvenido a ER-Soft.
ER-Soft con la ley orgánica de protección de datos
Política de cookies.
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación.
Si continúa navegando, consideramos que acepta su uso.
Más información pulsando aquí
X

¿Necesitas ayuda? Click

ayuda ER-Soft
X
Consulta a ER-Soft. *

 

*

 

* *Campos obligatorios.




X